SLCA-7
INSTALLATION & OPERATING MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts
Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at
www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and
manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.
39328.0003D 10/13 ©2013 Bunn-O-Matic Corporation
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - BUNN-O-MATIC CORPORATION

SLCA-7INSTALLATION & OPERATING MANUALBUNN-O-MATIC CORPORATIONPOST OFFICE BOX 3227SPRINGFIELD, ILLINOIS 62708-3227PHONE: (217) 529-6601 FAX: (21

Strona 2 - 39328.3 070913

10SLCA-7 PROGRAMMING LED DISPLAY PROGRAM MODE DESCRIPTIONProgram Mode: Used to change or enter new set-up values.To enter the Program Mode, Set t

Strona 3 - TABLE OF CONTENTS

11PROGRAMMING (Continued) LED DISPLAY PROGRAM MODE DESCRIPTIONMENU (-) (+)603 0MENU (-) (+)703 0MENU (-) (+)801 0MENU (-) (+)901 0MENU (-) (+)014

Strona 4 - USER NOTICES

12PROGRAMMING (Continued) LED DISPLAY PROGRAM MODE DESCRIPTIONMENU (-) (+)318MENU (-) (+)415MENU (-) (+)512 4MENU (-) (+)611MENU (-) (+)71#MENU (

Strona 5 - PLUMBING HOOK-UP

13PRIMING THE CONCENTRATE LINES 1. Open the dispenser door.2. Select Prime on the Function Selector Switch and Run on the Mode Selector Switch. 3. C

Strona 6

14DRAINING THE HOT WATER TANKCAUTION - The dispenser must be disconnected from the power source throughout these steps1. Disconnect the dispenser fro

Strona 7

15CLEANING & PREVENTATIVE MAINTENANCE General Cleaning and Sanitizing Procedures Note: The BUNN¨ SLCA-7 dispenser incorporates a “user select-able

Strona 8 - Tension Screw

16Weekly: Parts Washing and Sanitizing39328.3 01211314. When reassem-bling parts, be sure to align arrow on frother disk with flat on whipper mo-tor s

Strona 9 - EMPTY PRODUCT WARNING

17REPLACING THE PUMP TUBINGThe pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a

Strona 10 - SLCA-7 PROGRAMMING

18MENU (-) (+)CALIBRATING THE DISPENSERCALIBRATION MODE: The SLCA-7 is calibrated at the factory and does not normally need to be re-calibrated. To en

Strona 11 - PROGRAMMING (Continued)

19 LED DISPLAY CALIBRATION MODE DESCRIPTIONMENU (-) (+)4Cr u nMENU (-) (+)4CMENU (-) (+)5CE 0 0MENU (-) (+)6C- -MENU (-) (+)PC0 XXCALIBRATING THE

Strona 12

239328.3 070913BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTYBunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:1) Airpots, therma

Strona 13 - 39328.3 012113

20TROUBLESHOOTING GUIDE Error Codes When an error has occurred, all Door LED’s will be flashing. Open the Door to access the LED Display and re-cord th

Strona 14 - OPERATING THE DISPENSER

21Field Calibration of the Concentrate Pumps, Dispenser Flow Rates,and Hopper Powder ThrowThe factory set default values for the Pump & Dispenser

Strona 15

22Calibrating the Dispenser Flow RatesDecaf Coffee - Dispenser Flow Rate Calibration 1. Select RINSE on the Function Selector Switch, and PROGRAM of

Strona 16

239. Install the coffee BIB’s into the unit, and prime the pumps. Dispense several cups of both regular coffee and Decaf coffee. If either one or b

Strona 17 - PREVENTIVE MAINTENANCE

24ELECTRICAL WIRING DIAGRAM SLCA-739328.3 012113158151015201510141510125115+V+V-V-VGROUNDN/L2L1COMN.O.MAIN CONTROL BOARDJ15J3J11J6J5J11J41015MENU(-)(+

Strona 18 - CALIBRATING THE DISPENSER

3INTRODUCTIONThis equipment dispenses hot beverages or soups on demand from powdered product. It is indoor use only on a sturdy counter or shelf.TABLE

Strona 19 - MENU (-) (+)

4As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA),

Strona 20 - TROUBLESHOOTING GUIDE

5INITIAL SET-UP1. Apply the four non-skid pads from the parts box to the bottom of the legs.2. Remove the drip tray assembly and drip tray bracket f

Strona 21

6OPERATING CONTROLS AND INTERFACE1. Cup Size Buttons: Momentarily pushed to select beverage size to dispense.2. Stop Button: Momentary pushed to st

Strona 22 - 39328.3 101513

71011 8 9STOPMOCHA LATTEESPRESSODECAFCAPPUCCINOMOCHACAPPUCCINOHOT CHOCOLATEBLACK COFFEELATTESMALLLARGE5 3 1 2

Strona 23

8INSTALLING PUMP TUBING1. Loosen the thumbscrews securing the tubing retainer plates to the pump bodies and set the retainer plates aside.2. Depress

Strona 24 - Black Ink

9INITIAL FILL & HEAT1. Turn on the water supply and connect the dispenser to the power source. 2. Water will automatically flow into the tank to