SLCA-7INSTALLATION & OPERATING MANUALBUNN-O-MATIC CORPORATIONPOST OFFICE BOX 3227SPRINGFIELD, ILLINOIS 62708-3227PHONE: (217) 529-6601 FAX: (21
10SLCA-7 PROGRAMMING LED DISPLAY PROGRAM MODE DESCRIPTIONProgram Mode: Used to change or enter new set-up values.To enter the Program Mode, Set t
11PROGRAMMING (Continued) LED DISPLAY PROGRAM MODE DESCRIPTIONMENU (-) (+)603 0MENU (-) (+)703 0MENU (-) (+)801 0MENU (-) (+)901 0MENU (-) (+)014
12PROGRAMMING (Continued) LED DISPLAY PROGRAM MODE DESCRIPTIONMENU (-) (+)318MENU (-) (+)415MENU (-) (+)512 4MENU (-) (+)611MENU (-) (+)71#MENU (
13PRIMING THE CONCENTRATE LINES 1. Open the dispenser door.2. Select Prime on the Function Selector Switch and Run on the Mode Selector Switch. 3. C
14DRAINING THE HOT WATER TANKCAUTION - The dispenser must be disconnected from the power source throughout these steps1. Disconnect the dispenser fro
15CLEANING & PREVENTATIVE MAINTENANCE General Cleaning and Sanitizing Procedures Note: The BUNN¨ SLCA-7 dispenser incorporates a “user select-able
16Weekly: Parts Washing and Sanitizing39328.3 01211314. When reassem-bling parts, be sure to align arrow on frother disk with flat on whipper mo-tor s
17REPLACING THE PUMP TUBINGThe pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a
18MENU (-) (+)CALIBRATING THE DISPENSERCALIBRATION MODE: The SLCA-7 is calibrated at the factory and does not normally need to be re-calibrated. To en
19 LED DISPLAY CALIBRATION MODE DESCRIPTIONMENU (-) (+)4Cr u nMENU (-) (+)4CMENU (-) (+)5CE 0 0MENU (-) (+)6C- -MENU (-) (+)PC0 XXCALIBRATING THE
239328.3 070913BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTYBunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:1) Airpots, therma
20TROUBLESHOOTING GUIDE Error Codes When an error has occurred, all Door LED’s will be flashing. Open the Door to access the LED Display and re-cord th
21Field Calibration of the Concentrate Pumps, Dispenser Flow Rates,and Hopper Powder ThrowThe factory set default values for the Pump & Dispenser
22Calibrating the Dispenser Flow RatesDecaf Coffee - Dispenser Flow Rate Calibration 1. Select RINSE on the Function Selector Switch, and PROGRAM of
239. Install the coffee BIB’s into the unit, and prime the pumps. Dispense several cups of both regular coffee and Decaf coffee. If either one or b
24ELECTRICAL WIRING DIAGRAM SLCA-739328.3 012113158151015201510141510125115+V+V-V-VGROUNDN/L2L1COMN.O.MAIN CONTROL BOARDJ15J3J11J6J5J11J41015MENU(-)(+
3INTRODUCTIONThis equipment dispenses hot beverages or soups on demand from powdered product. It is indoor use only on a sturdy counter or shelf.TABLE
4As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA),
5INITIAL SET-UP1. Apply the four non-skid pads from the parts box to the bottom of the legs.2. Remove the drip tray assembly and drip tray bracket f
6OPERATING CONTROLS AND INTERFACE1. Cup Size Buttons: Momentarily pushed to select beverage size to dispense.2. Stop Button: Momentary pushed to st
71011 8 9STOPMOCHA LATTEESPRESSODECAFCAPPUCCINOMOCHACAPPUCCINOHOT CHOCOLATEBLACK COFFEELATTESMALLLARGE5 3 1 2
8INSTALLING PUMP TUBING1. Loosen the thumbscrews securing the tubing retainer plates to the pump bodies and set the retainer plates aside.2. Depress
9INITIAL FILL & HEAT1. Turn on the water supply and connect the dispenser to the power source. 2. Water will automatically flow into the tank to