Bunn LCA-2 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekspresy do kawy Bunn LCA-2. Bunn LCA-2 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
!
WA
RNI
N
G
HOT
LIQU
I
DS
!
A
V
E
R
T
I
SS
E
ME
N
T
L
I
Q
UI
DE
S
C
HA
U
DS
P
O
W
E
R
R
E
A
D
Y
P
O
R
T
I
ON
R
I
N
S
E
R
E
F
I
L
L
S
T
O
P
!
H
O
T
WA
T
E
R
INSTALLATION & OPERATING MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
www.bunnomatic.com
34766.0000J 01/07 ©2002 Bunn-O-Matic Corporation
LCA-2
LCA-2 PC
LCC-2
To obtain the Illustrated Parts Catalog, visit the Bunn-O-Matic website, at www.bunn.com. This is absolutely FREE,
and the quickest way to obtain the catalog. Contact Bunn-O-Matic Corporation at 1-800-286-6070 to obtain a paper
copy of the required Illustrated Parts Catalog mailed via U.S. Postal Service.
Przeglądanie stron 0
1 2 3 4 5 6 ... 33 34

Podsumowanie treści

Strona 1 - LCA-2 PC

! WARNING HOT LIQUIDS! AVERTISSEMENT LIQUIDES CHAUDSPOWERREADYPORTIONRINSEREFILLSTOP!HOT WATERINSTALLATION & OPERATING MANUALBUNN-O-MATIC CO

Strona 2 - CONTENTS

10FlavorGard™ FeatureFlavorGard™ is a patented feed back control loop that monitors the mixed product and adjusts the concentrate delivery rate to mai

Strona 3 - INTRODUCTION

11Rinse Procedure:1. Open the cabinet door and select Rinse on the Function Selector switch – close the door.2. Place a 2 Liter (1/2 Gal) container

Strona 4 - ELECTRICAL REQUIREMENTS

12PROGRAMMING THE DISPENSERRemove the lower splash guard assembly to access the digital programming module with LCD display.Press the Down Arrow key t

Strona 5 - PLUMBING HOOK-UP

13 MENU SCREEN ACTION DESCRIPTIONLOCK FLAVOR ? EXIT YESFLAVORS LOCKEDEXITLF DISP VOLUME(-) 4.0oz (+)RT DISP VOLUME(-)

Strona 6 - SETTING DISPENSER FLOW RATE

14TANK TEMP 180(-) EXIT (+)READY TEMP 175(-) EXIT (+)CABINET TEMP 65(-) EXIT (+)LF PRODUCT DISP.0GAL RESET?LF PRODUCT DISP.0GALRT PRODUCT

Strona 7 - Lubricate New Tube

15 MENU SCREEN ACTION DESCRIPTIONCAL LEFT PUMP ?PULL DISPENSECAL LF PUMP VOL(-) 43mL (+)CAL LF WTR FLOW ?PULL DISPENSERCAL LF WTR VO

Strona 8

16 MENU SCREEN ACTION DESCRIPTIONCAL RIGHT PUMP ?PULL DISPENSERCAL RT PUMP VOL(-) 43mL (+)CAL RT WTR FLOWPULL DISPENSERCAL RT WTR VO

Strona 9 - INITIAL FILL & HEAT

17 MENU SCREEN ACTION DESCRIPTIONBIB EMPTY -> 500(-) EXIT (+)XX REFILL -> 155(-) EXIT (+)WTR START DELAY(-) .15SEC (+)WTR

Strona 10 - Rinse Alarm Feature

18LOADING THE CONCENTRATE1. Thoroughly mix concentrate by vigorously shaking the product Bag-In-Box (BIB).2. Pull the BIB connector through the hole

Strona 11 - BIB Empty Lockout Feature

19Filling Cambros or other large containers:The dispenser is designed primarily for cups or other small containers that will fit under the dispense tip

Strona 12 - PROGRAMMING THE DISPENSER

2BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTYBunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:1) All equipment other than as s

Strona 13 - 34766 120105

20OPERATING THE PRESET PORTION CONTROL DISPENSER(Models LCA-2 PC, LCA-2C PC, LCA-2A PC)Set the Function Selector Switch to Normal and the Mode Select

Strona 14

21CLEANING & PREVENTATIVE MAINTENANCEGeneral Cleaning and Sanitizing ProceduresNote: The BUNN® Liquid Coffee Dispenser incorporates a “user select

Strona 15

22REPLACING THE PUMP TUBINGThe pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a

Strona 16

23DRAINING THE HOT WATER TANKCAUTION: The dispenser must be disconnected from the power source throughout these steps. 1. Disconnect the dispenser fr

Strona 17 - 34766 061605

24Activate the Dispenser within 5 sec. to dispense the pre-selected volume.34766 042304Front Panel LED Display MessagesAlternate Portion Dispens

Strona 18 - PRIMING THE CONCENTRATE LINES

25Troubleshooting (Continued)Replace BIB, see Loading the ConcentrateCheck BIB Connector Fittings Check Tubing Installat

Strona 19 - 34766 042304

26Screen Displayed Possible Cause Troubleshooting ProceduresDispenser Diagnostics-LCD DisplayTroubleshooting (Continued)34766 011604LF TARGE

Strona 20

27Screen Displayed Possible Cause Troubleshooting ProceduresTroubleshooting (Continued)34766 011604Service RequiredService RequiredService R

Strona 21

28Screen Displayed Possible Cause Troubleshooting ProceduresTroubleshooting (Continued)34766 010407EVAP TEMP SENSOR OUT OF RANGECHECK WIRE F

Strona 22 - REPLACING THE PUMP TUBING

29Field Calibration of the Concentrate Pumps / Dispenser Flow RatesThe factory set Default Values for the Pump & Dispenser Flow Rates are very acc

Strona 23 - DRAINING THE HOT WATER TANK

3USER NOTICESCarefully read and follow all notices on the equipment and in this manual. They were written for your protec-tion. All notices are to be

Strona 24 - Troubleshooting

3034766 120105Dispenser Flow Rate Calibration13. Press Down Arrow Key to display the CAL LF WTR FLO menu screen.14. Place a 64 Oz (2000 ml) graduated

Strona 25 - Troubleshooting (Continued)

31Field Calibrating the Empty BIB WarningThe dispenser will automatically turn on the Left or Right “REFILL LED”, see Operating Controls and Interface

Strona 26

3234766 01040734641.0000J 09/06 © 2002 BUNN-O-MATIC CORPORATION120 VOLTS AC 2 WIRE120/208-240 VOLTS AC 3 WIRE208-240 VOLTS AC 2 WIRESINGLE PHASE 5

Strona 27

3334641.0003A 01/07 © 2007 BUNN-O-MATIC CORPORATION120 VOLTS AC 2 WIRE120/208-240 VOLTS AC 3 WIRE208-240 VOLTS AC 2 WIRESINGLE PHASE 50/60HZJ14-1J

Strona 28

3434766 09270634641.0001J 09/06 © 2002 BUNN-O-MATIC CORPORATIONJ14-1J14-7J7-1J7-5J7-10J2-1J2 -8J3-1J3-6J4-1J4-5J5-1J5-3J6-1J6-5J6-10J6-15J6-20J1-1

Strona 29

4ELECTRICAL REQUIREMENTSCAUTION: The dispenser must remain disconnected from the power source until specified in Electrical Hook-Up. The LCA-2 and LC

Strona 30 - (Continued)

5PLUMBING REQUIREMENTSThe dispenser may be connected to a cold or hot water system (140°F Max.) with operating pressure between 20 and 90 psi (138 and

Strona 31

6SETTING DISPENSER FLOW RATEThe dispenser comes from the factory with flow restrictors in the mix chambers. With the restrictors in place the dispense

Strona 32 - SCHEMATIC WIRING DIAGRAM

7SELECTING THE CORRECT PUMP TUBINGThere are two pump tube sizes available for use with this dispenser. To determine the correct tubing for you applica

Strona 33

8OPERATING CONTROLS AND INTERFACE1a. Dispense Handles: Pull and Hold to dispense product.1b. Dispense Switches: Push and Release to dispense product f

Strona 34 - 34766 092706

9INITIAL FILL & HEAT1. Select Normal on the Function Selector Switch and Run on the Mode Selector Switch.2. Confirm the water supply is on.3. Co

Komentarze do niniejszej Instrukcji

Brak uwag