BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
www.bunnomatic.com
OPERATING & SERVICE MANUAL
AFPO-2
AFPO-2 SL
AFPO-3
AFPO-3 SL
F
L
A
V
O
R
I
N
P
U
T
1
2
W
A
T
E
R
I
N
P
U
T
F
L
A
V
O
R
O
U
T
P
U
T
F
L
A
V
O
R
O
U
T
P
U
T
W
A
T
E
R
O
U
T
P
U
T
W
A
T
E
R
O
U
T
P
U
T
R
E
F
I
L
L
M
A
I
N
P
O
W
E
R
2
1
1
2
F
L
A
V
O
R
IN
P
U
T
1
2
W
A
T
E
R
IN
P
U
T
R
E
F
IL
L
M
A
IN
P
O
W
E
R
2
1
1
2
3
3
3
F
L
A
V
O
R
O
U
T
P
U
T
F
L
A
V
O
R
O
U
T
P
U
T
W
A
T
E
R
O
U
T
P
U
T
F
L
A
V
O
R
O
U
T
P
U
T
W
A
T
E
R
O
U
T
P
U
T
W
A
T
E
R
O
U
T
P
U
T
28791.0000E 4/01 ©1998 Bunn-O-Matic Corporation
BUNN
®
Przeglądanie stron 0
1 2 3 4 5 6 ... 24 25

Podsumowanie treści

Strona 1 - AFPO-3 SL

BUNN-O-MATIC CORPORATIONPOST OFFICE BOX 3227SPRINGFIELD, ILLINOIS 62708-3227PHONE: (217) 529-6601 FAX: (217) 529-6644www.bunnomatic.comOPERATING &a

Strona 2 - 28791 051599

10SERVICECIRCUIT BOARDOFFOFFONOFFOFFONOFFOFFONOFFOFFONFIG. 2 CIRCUIT BOARDP1520Location:The circuit board is located inside the autofill box,mounted o

Strona 3 - PIPING DIAGRAM

11SERVICELocation:The fuse holder is located on the lower right frontof the autofill box just to the left of the power cord.Test Procedure:1. Disconne

Strona 4 - MIX RATIO ADJUSTMENTS

12P1522FIG. 7 MAIN ON/OFF SWITCH TERMINALSBLK from Fuse HolderBLK to Solenoid (Water)Switch #2 AFPO-2 & 3MAIN ON/OFF SWITCHFLAVORINPUT1 2WATERIN

Strona 5

13Probe Boxes:1. Disconnect the signal cable from the probe boxes.2. Remove probe box from CDS hopper.3. Place the switch on the probe box in the “HIG

Strona 6 - OPERATING CONTROLS

14FLAVORINPUT1 2WATERINPUTREFILLMAINPOWER2112333FLAVOROUTPUTFLAVOROUTPUTWATEROUTPUTFLAVOROUTPUTWATEROUTPUTWATEROUTPUTSERVICE (cont.)PUMP (FLAVOR) ON

Strona 7 - TROUBLESHOOTING

15SERVICE (cont.)REFILL SWITCHESFIG. 14 REFILL SWITCHESLocation:The refill switches are located on the upper rightfront of the autofill box.Test Proce

Strona 8

16SERVICE (cont.)SOLENOIDSFIG. 16 SOLENOIDSLocation:The solenoids are located inside the autofill box.Test Procedure:1. Disconnect the dispenser from

Strona 9 - Troubleshooting

17SERVICE (cont.)SOLENOID (WATER) ON/OFF SWITCHESFLAVORINPUT1 2WATERINPUTREFILLMAINPOWER2112333FLAVOROUTPUTFLAVOROUTPUTWATEROUTPUTFLAVOROUTPUTWATERO

Strona 10 - Wiring Diagrams

18FLAVORINPUT1 2WATERINPUTREFILLMAINPOWER2112333FLAVOROUTPUTFLAVOROUTPUTWATEROUTPUTFLAVOROUTPUTWATEROUTPUTWATEROUTPUTSERVICE (cont.)TEST/OPERATE ON/

Strona 11 - Harness/Control Board

19SERVICE (cont.)VACUUM/SUPPLY PUMP ASSEMBLYFIG. 22 VACUUM/SUPPLY PUMP ASSEMBLYP1521Location:The vacuum/supply pumps are located inside theautofill bo

Strona 12 - SERVICE (cont.)

2INTRODUCTIONThis equipment supplies a liquid concentrate mixed with water at various ratios to the hoppers on the CDS-2 orCDS-3 dispensers. It is f

Strona 13 - AFPO-2 & 3

20SERVICE (cont.)VACUUM/SUPPLY PUMP TUBE INSTALLATIONFIG. 24 TUBING START POSITIONP1542ROLLERSPUMPHEADTUBINGKEYENTRYPORTEXITPORTFIG. 25 TUBING LOADED

Strona 14 - 28791 040501

21VACUUM SWITCHESFIG. 26 VACUUM SWITCHESLocation:The vacuum switches are located inside autofillbox, mounted on the left side of the solenoid mount-in

Strona 15

22FLAVORINPUT1 2WATERINPUTFLAVOROUTPUTFLAVOROUTPUTWATEROUTPUTWATEROUTPUTREFILLMAINPOWER2112BUNN®Moving Parts.Do not operateunit with thispanel remov

Strona 16

23GRNSOL#1SOL#2PUMP#1PUMP#210AMPMAIN ON/OFFSWITCHREFILL ON/OFFSWITCH #1REFILL ON/OFFSWITCH #2 J4-1 2 3 4 5 6

Strona 17

24GRNSOL#1SOL#2PUMP#1PUMP#210AMPMAIN ON/OFFSWITCHREFILL ON/OFFSWITCH #1REFILL ON/OFFSWITCH #3REFILL ON/OFFSWITCH #2 J4-1 2 3 4

Strona 18

2528791 011500GRNSOL#1SOL#2PUMP#1PUMP#210AMPMAIN ON/OFFSWITCHREFILL ON/OFFSWITCH #1REFILL ON/OFFSWITCH #2 J4-1 2 3 4 5

Strona 19

3ELECTRICAL REQUIREMENTSCAUTION - The dispenser must be disconnected from the power source until specified in Initial Set-Up.The 120 volt version of t

Strona 20

428791 0405015. Connect one end of input hoses to the auto refill box and the other end to the product container. Productcontainer connectors (BIB) ar

Strona 21

5Mix ratio (water/flavor) Time for FLAVOR OUTPUT (1/2 cup) Time for WATER OUTPUT (1 cup)1+1 assume 20 sec. or obtain time per note below 40 sec. or 2

Strona 22 - 28791 011500

6OPERATING CONTROLSA. MAIN POWER ON/OFFThe main power ON/OFF switch is located on the right of the front panel just above the power cord.B. REFILL CIR

Strona 23 - SCHEMATIC WIRING DIAGRAM

7TROUBLESHOOTINGA troubleshooting guide is provided to suggest probable causes and remedies for the most likely problemsencountered. If the problem

Strona 24

8TROUBLESHOOTING (cont.)PROBLEMPROBABLE CAUSE6. Main ON/OFF switch7. Probe box LOW/OFF/HIGHswitches8. Circuit board9. Vacuum switch10. Vacuum/Suppl

Strona 25

9SERVICEThis section provides procedures for testing andreplacing various major components used in thisdispenser should service become necessary