BUNN® TECHNICAL TRAININGAutoPOD™
AutoPOD™ Training Manual10Calibrating Brew Flow RateAfterinitialstart-up,theowrateforthebrewtankmustbecalibrated. Step 1: Enter the progr
Bunn-O-Matic Corporation11Step 4: After entering the ounces collected, the machine changed the default time to the actual calibrated dispense time to
Unit ObjectivesUnit 3 Machine coMpositionGiven a realistic scenario in which the learner has access to the machine’s internal components the learner
Bunn-O-Matic Corporation13Machine CompositionExterior OverviewProduct Outlets and Removable Parts• Pod Door• Drip Tray and Grate• Booster Tray and
AutoPOD™ Training Manual14Machine Function and OperationsMain Control BoardThe main control is the brain of the brewer. The control board is the singl
Bunn-O-Matic Corporation15Waterenterstheinletvalveandisregulatedbya.175owcontrolandentersthebottomofthehotwatertank.Thetankwi
AutoPOD™ Training Manual16Heating SystemEach heating element is part of the tank and is rated between 1300-1450 watts at 120VAC. The element wires are
Bunn-O-Matic Corporation17Step 4: After ejecting the coffee pod, the pod holder rotates forward by a set time built in the software (approx. 5 sec-ond
Unit ObjectivesUnit 4 preventive MaintenanceGiven a realistic scenario depicting a machine requiring a preventive maintenance, the learner will be ab
Bunn-O-Matic Corporation19Preventive MaintenanceIn order to maintain proper operation and long service life BUNN® recommends performing the preventive
IndexUnit 1: Installation Site Requirements ...
AutoPOD™ Training Manual20 □ Insert 26367.0000 cleaning brush from the underside into the coffee outlet hole (rear) and work back and forth □ Use clea
Bunn-O-Matic Corporation21Step 8: Calibrate the maximum H2O (Hot Water Tank) time □ Access programming and go to CALIBRATE FLOW ? menu □ Depress NO bu
Unit ObjectivesUnit 5 troubleshootingGiven a realistic scenario depicting one of several possible machine malfunctions, the learner will be able to e
Bunn-O-Matic Corporation23Troubleshooting and RepairThe AutoPOD™ brewer features on-board troubleshooting. Since all of the machine’s components are c
AutoPOD™ Training Manual24 TEST SWITCHES will give you the option of pressing the control switch individually and displaying the switc
Bunn-O-Matic Corporation25Warning MessagesPressure switch activation during single cup brew, displays “Pressure Too High on the LCD”The brew process i
AutoPOD™ Training Manual26 The heating relay has been activated for more than 6 minutes. Themessagewillappea
Bunn-O-Matic Corporation27Hot Water Tank RemovalThe hot water tank will need to be replaced when the heating element no longer works.Step 1: Disconnec
AutoPOD™ Training Manual28Step 5: Disconnect black wire from limit thermostat going to heater relay.Step 6: Leave all wires connected to relay and rem
Bunn-O-Matic Corporation29Triac Map1. Output to heater relay contacts (TH1)2. Hot water solenoid (TH2)3. Brew solenoid (TH4)4. Optional booster pump (
Unit ObjectivesUnit 1 installationGiven a realistic scenario depicting a new site install, the learner will be able to install and setup the brewer f
AutoPOD™ Training Manual4InstallationSite RequirementsSpace• AutoPOD™ is only for indoor use on a sturdy counter or shelf• AutoPOD™ dimensions is 15
Bunn-O-Matic Corporation5AutoPOD™ with Pump ModelPressureregulatorwithttingssecuretothe.75-11.5NH(HoseThread)ttingattherearofthebre
Unit ObjectivesUnit 2 setupGiven a realistic scenario depicting a new site install, the learner will be able to install and setup the brewer for cust
Bunn-O-Matic Corporation7Setup and ProgrammingUser InterfaceThe switch decal adheres to the front housing over the electronic switch and LCD (Liquid C
AutoPOD™ Training Manual8Programming Menus Brew Lockout Prevents brewing if the water temperature is less than the “SET READY” te
Bunn-O-Matic Corporation9ENTER ASSET # ?NO YES Enter Asset # Allows you to enter in an optional 4 digit number. This can be useful for t