OPERATING & SERVICE MANUALBUNN-O-MATIC CORPORATIONPOST OFFICE BOX 3227SPRINGFIELD, ILLINOIS 62708-3227PHONE: (217) 529-6601 FAX: (217) 529-6644w
10SERVICE (cont.)Electronic Controls Location:The electronic control assembly is located inside the rear of the dispenser. Access will also be needed
11SERVICE (cont.)Electronic Controls (cont.)Liquid Level Control Test Procedure1. Disconnect the dispenser from the power source.2. Check the voltag
12SERVICE (cont.)Electronic Controls (cont.)7. Reconnect the pink wire to terminal 5 of the elec-tronic control assembly.8. Loosen the compression fi
13SERVICE (cont.)Electronic Controls (cont.)If the indicator was on or blinking, the temperature sen-sor is operating properly, proceed to #7.If the
14SERVICE (cont.)Electronic Controls (cont.)Electronic Controls Removal and ReplacementNOTE - Each electronic control assembly is calibrated to a temp
1510420 060305SERVICE (cont.)Electronic Controls (cont.)Adjustments The H5X dispenser holds the water temperature at the threshhold of boiling.
16SERVICE (cont.)Limit ThermostatLocation:The limit thermostat is located on the tank lid.To test the limit thermostat, access will also be needed to
17SERVICE (cont.)Safety Overflow SwitchLocation:The safety overflow switch is located inside the rear of the dispenser inside the copper overflow cup.For
18SERVICE (cont.)Solenoid ValveLocation:The solenoid valve is located inside the rear of the dispenser on the right side near the bottom.To t
19SERVICE (cont.)Tank HeaterLocation:The tank heater is located in the tank lid.Test Procedure:1. Disconnect the dispenser from the power source.2.
210420 020608BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTYBunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:1) All equipment oth
20WIRING DIAGRAMS10420 121598
21WIRING DIAGRAMS10420 121598
22WIRING DIAGRAMS10420 091902
3CONTENTS Introduction ...2 Warranty ...2 User N
4ELECTRICAL REQUIREMENTSCAUTION - The dispenser must be disconnected from the power source until specified in Initial Set-Up.This dispenser requires 2-
5INITIAL SET-UPCAUTION - The dispenser must be disconnected from the power source throughout the initial set-up, except when specified in the instructi
6TROUBLESHOOTINGA troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the proble
7TROUBLESHOOTING (cont.)Problem Probable Cause Remedy Automatic refill will not oper-ate after drawing hot water.Water flows into the tank con-tin
8TROUBLESHOOTING (cont.)Problem Probable Cause Remedy Water boils continuously.Dispenser is making unusual noises.Ready indicator will not li
9SERVICEThis section provides procedures for testing and replacing various major components used in this dispenser should service become nec