REGULARDECAFEREFILLREADYPOWERRINSECARAFE´HOT WATERSTOP !2. Press and hold when in manual mode or press and release when in portion mode1. Press f
10INITIAL FILL & HEAT1. Select Normal on the Function Selector Switch and Run on the Mode Selector Switch.2. Confirm the water supply is on.3. Co
11Rinse Alarm FeaturePeriodic rinsing of the mix chambers and dispense tips is essential for proper maintenance and optimum performance of the dispens
12PROGRAMMING THE DISPENSEROpen the dispenser door to access the digital programming module with LED display.Two basic modes are available to the oper
13Regular Dispense Total Displays Total Regular Coffee Dispensed (XX.X Gal)Decaf Dispense Total Displays Total Decaf Coffee Dispensed (XX.X Gal)Displa
14PROGRAMMING THE DISPENSER (Cont.)Program Mode: Used to change or enter new set-up values.To enter the Program Mode, Set the RUN/NIGHT/PROGRAM Switch
15Right (Decaf) Dispense Total LCD DISPLAY PROGRAM MODE DESCRIPTIONPROGRAMMING THE DISPENSER (Cont.)Program Mode (Continued)Empty Product Thresho
16PRIMING THE CONCENTRATE LINES1. Open the dispenser door.2. Select Prime on the Function Selector Switch and Run on the Mode Selector Switch.3. Clo
17OPERATING THE DISPENSERSet the Function Selector Switch to “Normal” and the Mode Selector Switch to “Run.”1A. Push and Hold Dispense Mode (Cup at a
18CLEANING & PREVENTATIVE MAINTENANCEGeneral Cleaning and Sanitizing ProceduresNote: The BUNN® LCC-2 LP dispenser incorporates a “user selectable”
19REPLACING THE PUMP TUBINGThe pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a
239288 050511BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTYBunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:1) All equipment oth
20Right (Decaf) Water Rate Set PRIME-NORMAL-RINSE switch to RINSE position. Press and hold Decaf Dispense Switch until flow stops (20 sec.) Refer to Fi
21CALIBRATING THE DISPENSER (Cont.) LCD DISPLAY CALIBRATION MODE DESCRIPTIONRight (Decaf) Water Rate Enter Liters collected from the 20 sec. test
22 LED DISPLAY ERROR DESCRIPTION/TROUBLESHOOTINGTROUBLESHOOTING GUIDEError CodesWhen an error has occurred, all Door LED’s will be flashing. Open
23TROUBLESHOOTING GUIDE (Cont.)Error Codes (Continued) LED DISPLAY ERROR DESCRIPTION/TROUBLESHOOTINGTank Temp Sensor Failed Sensor Reading Out Of
24(Continued Next Page)Field Calibration of the Concentrate Pumps & Dispenser Flow RatesThe factory set default values for the Pump & Dispense
25Field Calibration of the Concentrate Pumps & Dispenser Flow Rates(Continued)5. Place a 1500 to 2000 ml graduated container under Left Dispense
2639288 083106BLU/BLK-16RED-22WHT/BLK-22WHT/BLU-22WHT/BLU-22WHT/BLK-22TAN-22MBOARDSWITCH & LEDRED/BLK-18RPM SENSORRIGHT PUMPMRPM SENSORLEFT PUMPWH
3Warranty ...
4USER NOTICESCarefully read and follow all notices on the equipment and in this manual. They were written for your protec-tion. All notices are to be
5ELECTRICAL REQUIREMENTSRefer to Data Plate on dispenser, and local/national electrical codes to determine circuit requirements.WARNING - If the power
6INITIAL SET-UPNOTE: The LCC-2 LP weighs approximately 70 lbs. (32 kg). If necessary, use more than one person when lifting or moving the dispenser.
7OPERATING CONTROLS AND INTERFACERefer to the photos on the following page for the location of these features.1. Dispense Switches: Push to dispense
8141112132 41 37 8 5 6 9 1039288 083106
9INSTALLING PUMP TUBINGINSTALLING THE PUMP TUBINGRefer to the Tube Replacement Instruction inside the Cabinet door.1. Loosen the thumbscrew securing
Komentarze do niniejszej Instrukcji