BUNN
®
OPERATING & SERVICE MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
28791.0001B 1/00 ©1998 Bunn-O-Matic Corporation
AF PR-2
AF PR-3
AFPR-3 VERSION DISCONTINUED
The information in this manual
is no longer current.
Przeglądanie stron 0
1 2 3 4 5 6 ... 16 17

Podsumowanie treści

Strona 1 - AF PR-3

BUNN®OPERATING & SERVICE MANUALBUNN-O-MATIC CORPORATIONPOST OFFICE BOX 3227SPRINGFIELD, ILLINOIS 62708-3227PHONE: (217) 529-6601 FAX: (217) 529-

Strona 2 - USER NOTICES

10Removal and Replacement::1. Remove the wires from the switch terminals.2. Compress the clips inside the autofill box and gently push the switch thr

Strona 3 - ELECTRICAL HOOk-UP

11FIG. 8 PROBE SWITCHES Probe Boxes:1. Disconnect the signal cable from the probe boxes.2. Remove probe box from CDS hopper.3. Place the switch on

Strona 4 - TROUBLESHOOTING

12SERVICE (cont.)REFILL SWITCHESFIG. 12 REFILL SWITCHESLocation: The refill switches are located on the upper right front of the autofill box. Test Pr

Strona 5 - OPERATING CONTROLS

13SERVICE (cont.)VACUUM/SUPPLY PUMP ASSEMBLYFIG. 16 VACUUM/SUPPLY PUMP ASSEMBLYP1560Location: The vacuum/supply pumps are located inside the autofill

Strona 6 - TROUBLESHOOTING (cont.)

14SERVICE (cont.)VACUUM/SUPPLY PUMP TUBE INSTALLATION1. Separate the pump head from the pump body. Hold pump head as shown in Fig. 18, with roller in

Strona 7

15VACUUM SWITCHESFIG. 16 VACUUM SWITCHESLocation: The vacuum switches are located inside autofill box, mounted on the left side of the mounting brack

Strona 8

1628791.1 011500

Strona 9

1728791.1 011500

Strona 10 - SERVICE (cont.)

2INTRODUCTIONThis equipment supplies a premixed liquid product to the hoppers on the CDS-2 or 3 dispensers. It is for indoor use only on a sturdy co

Strona 11

3INITIAL SET-UPNOTE: This refill unit should not be used to initially fill the hopper. Running the motor for extended periods will trip the thermal swit

Strona 12 - #3 AFPR-3 ONLY

4CLEANINGRECOMMENDED WEEkLY CLEANING:This should be done in conjunction with the recommended weekly cleaning of your CDS-2 or CDS-3 machine. TheCDS Ho

Strona 13

5OPERATING CONTROLSA. MAIN POWER ON/OFFThe main power ON/OFF switch is located on the right of the front panel just above the power cord.B. REFILL CIR

Strona 14

6PROBLEM1. Empty product container2. No power or incorrect voltage to the dispenser3. Signal cable unplugged4. Hopper is full5. Fuse and fuse holder6.

Strona 15

7SERVICE This section provides procedures for testing and replacing various major components used in this dispenser should service become necessary.

Strona 16 - 28791.1 011500

8Removal and Replacement:1. Disconnect the ten pin plug from the main wiring harness to the circuit board.2. Remove the six #4-40 screws and spacer

Strona 17

9FIG. 4 FUSE HOLDERFUSE AND FUSE HOLDER P1561Location: The fuse holder is located on the lower right front of the autofill box just to the left of the