LCA-2 ICINSTALLATION & OPERATING GUIDEBUNN-O-MATIC CORPORATIONPOST OFFICE BOX 3227SPRINGFIELD, ILLINOIS 62708-3227PHONE: (217) 529-6601 FAX: (2
10Rinse Alarm FeaturePeriodic rinsing of the mix chambers and dispense tips is essential for proper maintenance and optimum performance of the dispens
11PROGRAMMING THE DISPENSERRemove the lower splash guard assembly to access the digital programming module with LCD display.Press the Down Arrow key t
12SET PASSWORD ?(-) 0 (+)SELECT UNITSENG EXIT METRICCHILLED UNIT ?NO EXIT YES RINSE ALARM ?NO EXIT YES If NO - go to BIB
13 MENU SCREEN ACTION DESCRIPTIONCAL LEFT PUMP ?PULL DISPENSECAL LF PUMP VOL(-) 43mL (+)CAL LF WTR FLOW ?PULL DISPENSERIf NO - go to
14 MENU SCREEN ACTION DESCRIPTIONCAL LF WTR VOL(-) 36.0OZ (+)CAL LEFT SIDE ? EXIT YES CAL RIGHT SIDE ? EXIT YES CAL RI
15 MENU SCREEN ACTION DESCRIPTIONBIB EMPTY -> 250(-) EXIT (+)WTR START DELAY(-) .15SEC (+)WTR STOP DELAY(-) .15SEC (+)TEST LED’S
16LOADING THE CONCENTRATE1. Thoroughly mix concentrate by vigorously shaking the product Bag-In-Box (BIB).2. Pull the BIB connector through the hole
17Filling Cambros or other large containers:The dispenser is designed primarily for cups or other small containers that will fit under the dispense tip
18CLEANING & PREVENTATIVE MAINTENANCEGeneral Cleaning and Sanitizing ProceduresNote: The BUNN® Liquid Coffee Dispenser incorporates a “user select
19REPLACING THE PUMP TUBINGThe pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a
238059 050511BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTYBunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:1) All equipment oth
20Activate the Dispenser within 5 sec. to dispense the pre-selected volume.Front Panel LED Display MessagesAlternate Portion Dispenser Volume #2 has b
21Troubleshooting (Continued)Replace BIB, see Loading the ConcentrateCheck BIB Connector Fittings Check Tubing Installat
22Screen Displayed Possible Cause Troubleshooting ProceduresDispenser Diagnostics-LCD DisplayTroubleshooting (Continued)LF TARGET RPMTOO HIGH !!TU
23Screen Displayed Possible Cause Troubleshooting ProceduresTroubleshooting (Continued)LEFT PUMP FAULT! CHK PUMP WIRING CHK RPM SENSOR CHK TUBIN
24Field Calibration of the Concentrate Pumps / Dispenser Flow RatesThe factory set Default Values for the Pump & Dispenser Flow Rates are very acc
25Dispenser Flow Rate Calibration13. Press Down Arrow Key to display the CAL LF WTR FLO menu screen.14. Place a 64 Oz (2000 ml) graduated container un
2638059 09270634641.0002C 09/06 © 2005 BUNN-O-MATIC CORPORATION120 VOLTS AC 2 WIRESINGLE PHASE 50/60HZJ14-1J14-7J18-1J18-6J18-9J7-1J7-5J7-10J2-1J
3Warranty...2Introd
4USER NOTICESCarefully read and follow all notices on the equipment and in this manual. They were written for your protec-tion. All notices are to be
5ELECTRICAL REQUIREMENTSCAUTION: The dispenser must remain disconnected from the power source until specified in Electrical Hook-Up. The LCA-2 IC dis
6DISPENSER FLOW RATEThe dispenser comes from the factory with flow rate set at 1.8 oz./sec (53.2 ml/sec).INITIAL SET-UPNOTE: The LCA-2 IC weighs appro
7SELECTING THE CORRECT PUMP TUBINGThere are two pump tube sizes available for use with this dispenser. Look up the recommended tube size for the mix r
8OPERATING CONTROLS AND INTERFACE1. Dispense Switches: Pull and Hold to dispense product.2. Stop Switch: Momentary switch stops all dispense functio
9INITIAL POWER-UP1. Select Normal on the Function Selector Switch and Run on the Mode Selector Switch.2. Confirm the water supply is on.3. Connect th