Bunn CDBCF Airpot Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekspresy do kawy Bunn CDBCF Airpot. Bunn CDBCF Airpot User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
www.bunnomatic.com
OPERATING & SERVICE MANUAL
CEZ, CEZF,
CDBC, CDBCF
Airpot,
Thermal Carafe &
Thermal Server Brewers
29253.0000F 02/04 ©1999 Bunn-O-Matic Corporation
BUNN
M
A
N
U
F
A
C
T
U
R
E
D
B
Y
B
U
N
N
-O
-M
A
T
IC
C
O
R
P
O
R
A
T
IO
N
SP
R
IN
G
F
IE
L
D
, IL
L
IN
O
IS
, U
.S
.A
.
M
O
D
E
L
S
/N
V
O
L
T
S
A
.C
.
A
M
P
W
A
T
T
S
P
H
A
S
E
W
IR
E
H
E
R
T
Z
C
O
V
E
R
E
D
U
N
D
E
R
O
N
E
O
R
M
O
R
EO
F
T
H
E
F
O
L
L
O
W
IN
G
P
A
T
E
N
T
S
:
O
N
E
O
R
M
O
RE
O
T
H
E
R
P
A
T
E
N
T
S
M
A
Y
B
E
P
E
N
D
IN
G
BUNN
M
A
N
U
F
A
C
T
U
R
E
D
B
Y
B
U
N
N
-O
-
M
A
T
IC
C
O
R
P
O
R
A
T
IO
N
S
P
R
IN
G
F
IE
L
D
, IL
L
IN
O
I
S
, U
.S
.A
.
M
O
D
E
L
S
/N
V
O
L
T
S
A
.C
.
A
M
P
W
A
T
T
S
P
H
A
S
E
W
IR
E
H
E
R
T
Z
C
O
V
E
R
E
D
U
N
D
E
R
O
N
E
O
R
M
O
R
E
O
F
T
H
E
F
O
L
L
O
W
IN
G
P
A
T
E
N
T
S
:
O
N
E
O
R
M
O
R
E
O
T
H
E
R
P
A
TE
N
T
S
M
A
Y
B
E
P
E
N
D
IN
G
DISC
O
N
N
E
C
T FRO
M
PO
W
ER SOUR
CE
B
EFO
RE REM
O
VA
L OF A
N
Y PANEL O
R
R
EPLA
CE
M
EN
T OF A
NY
C
O
M
PONE
NT!
W
ARNING
!
CAUTION :
W
A
R
M
E
R
S
A
N
D
S
U
R
F
A
C
E
S
A
R
E H
O
T
Przeglądanie stron 0
1 2 3 4 5 6 ... 33 34

Podsumowanie treści

Strona 1 - Thermal Server Brewers

BUNN-O-MATIC CORPORATIONPOST OFFICE BOX 3227SPRINGFIELD, ILLINOIS 62708-3227PHONE: (217) 529-6601 FAX: (217) 529-6644www.bunnomatic.comOPERATING &a

Strona 2 - 29253 021604

Page 10TROUBLESHOOTINGA troubleshooting guide is provided to suggest probable causes and remedies for the most likely problemsencountered. If the pro

Strona 3 - USER NOTICES

Page 11Will not fill or refillFill or refill does not shut "OFF"(ON/OFF Switch "ON")PROBABLE CAUSE REMEDYPROBLEM1. Power off to br

Strona 4 - PLUMBING REQUIREMENTS

Page 12TROUBLESHOOTING (cont.)Fill or refill does not shut "OFF" (ON/OFF Switch "ON") (cont)Fill or refill does not shut "OFF

Strona 5 - OPERATING CONTROLS

Page 13TROUBLESHOOTING (cont.)PROBLEM PROBABLE CAUSEREMEDYHEATING CIRCUIT1. Display flashing (CDBC-APS/TC/TS/TSR) or ready light flashing(CEZ-APS/TS/T

Strona 6 - CLEANING

Page 14TROUBLESHOOTING (cont.)PROBLEM PROBABLE CAUSE REMEDYWater does not heat to propertemperature (cont.)IMPORTANT: Make sure no tem-perature tests

Strona 7

Page 15TROUBLESHOOTING (cont.)PROBLEM PROBABLE CAUSE REMEDYSpitting or excessive steaming(cont.)Brewer is making unusual noises2a. Temperature Probe (

Strona 8 - Adjusting Brew Volumes

Page 16TROUBLESHOOTING (cont.)PROBLEM PROBABLE CAUSE REMEDYBREWING CIRCUITBrew cycle will not start 1. Display flashing (CDBC-APS/TC/TS/TSR) or ready

Strona 9 - Pulse Brew Setup Procedure

Page 17TROUBLESHOOTING (cont.)PROBLEM PROBABLE CAUSE REMEDYBREWING CIRCUIT (cont.)If the start switch (CEZ-APS/TS/TSR) or switch panel (CDBC-APS/TC/TS

Strona 10 - TROUBLESHOOTING

Page 18TROUBLESHOOTING (cont.)PROBLEM PROBABLE CAUSE REMEDYBREWING CIRCUIT (cont.)Dripping from sprayheadWeak beverage1. Lime build up2. Dispense valv

Strona 11 - Water Sensing Thresh

Page 19TROUBLESHOOTING (cont.)PROBLEM PROBABLE CAUSE REMEDYBREWING CIRCUIT (cont.)Dry coffee grounds remain in thefunnel1. Sprayhead2. Funnel loadingM

Strona 12 - Adjustment Procedures

Page 2INTRODUCTIONThis equipment will automatically brew a half-gallon batch of coffee into an awaiting server at the press of abutton. A hot water f

Strona 13 - 29253 111103

Page 20DIAGNOSTICSIntermittent flashing of the READY indicator (Model CEZ) or the bank of temperature indicators (Model CDBC)indicates that a fault ex

Strona 14

Page 21BUNNMANUFACTURED BY BUNN-O-MATIC CORPORATION SPRINGFIELD, ILLINOIS, U.S.A.MODELS/NVOLTS A.C. AMP

Strona 15

Page 22BUNNMANUFACTURED BY BUNN-O-MATIC CORPORATION SPRINGFIELD, ILLINOIS894 589.253 c128.894 588.855 129.173 588.694 129.517 588.8

Strona 16

Page 23

Strona 18 - Initial

Page 25BUNNMANUFACTURED BY BUNN-O-MATIC CORPORATION SPRINGFIELD, ILLINOIS, U.S.A.MODELS/NVOLTS A.C. AMP

Strona 19

Page 26BUNNMANUFACTURED BY BUNN-O-MATIC CORPORATION SPRINGFIELD, ILLINOIS, U.S.A.MODELS/NVOLTS A.C. AMP

Strona 20 - DIAGNOSTICS

Page 27BUNNMANUFACTURED BY BUNN-O-MATIC CORPORATION SPRINGFIELD, ILLINOIS, U.S.A.MODELS/NVOLTS A.C. AMP

Strona 21 - WARMERS AND SURFACES ARE HOT

Page 28BUNNMANUFACTURED BY BUNN-O-MATIC CORPORATION SPRINGFIELD, ILLINOIS, U.S.A.MODELS/NVOLTS A.C. AMP

Strona 22

Page 29Location:The tank heater is located inside the tank andsecured to the tank bottom.Test Procedures:1. Disconnect the brewer from the power suppl

Strona 23

Page 3USER NOTICESCarefully read and follow all notices in this manual and on the equipment. All labels on the equipment shouldbe kept in good condit

Strona 24

Page 30P1856SERVICE (cont.)TANK HEATER (Cont.)BLK to Control BoardWHI or RED to TerminalBlockFIG. 14 TANK HEATER WIRING17. Install tank assembly onto

Strona 25 - AND SURFACES ARE HOT

Page 31TRM2J1J2J3J4J5J6J7TRM1CAUTION :WARMERS AND SURFACES ARE HOTSERVICE (cont.)REFILL VALVELocation:The refill valve is located inside the trunk on

Strona 26 - 29253 091603

Page 32SCHEMATIC WIRING DIAGRAM CDBC-APS/TS/TSR29253 111103EARLY MODELSSOL29257.0000B 12/99 ©1998 BUNN-O-MATIC CORPORATIONTANK HEATERL1GRNGRNRED-

Strona 27

Page 33SCHEMATIC WIRING DIAGRAM CEZ-APS/TS/TSRWHI29341.0000B 6/99 ©1998 BUNN-O-MATIC CORPORATIONWHIWHIBREW SWITCHTANK HEATERGRNRED-14 (MODEL 35)W

Strona 28 - BLK from Terminal

Page 34LATE MODELS29253 021604SOLSCHEMATIC WIRING DIAGRAM CDBC 15, 20 & 35 APS/TC/TS29257.0001D 02/04 ©1999 BUNN-O-MATIC CORPORATIONTANK HEA

Strona 29 - Wiring Diagrams

Page 4ELECTRICAL REQUIREMENTSCAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up.Model 15 has an attache

Strona 30 - WHI or RED to Terminal

Page 5OPERATING CONTROLSModel CEZ-APS/TS/TSRON/OFF SWITCHPlacing the "ON/OFF" switch in the "ON" upper position enables thebrew ci

Strona 31

Page 6INITIAL SET-UP1. Insert an empty funnel into the funnel rails.2. Place an empty server under the funnel.3. Connect the brewer to the power sourc

Strona 32 - EARLY MODELS

Page 7CEZ-APS/TS/TSR ADJUSTMENTS & OPTIONAL SETTINGS

Strona 33 - SINGLE PHASE

Page 8CDBC-APS/TC/TS/TSR ADJUSTMENTS & OPTIONAL SETTINGSSetting Brew TemperatureThe brewer is factory set to brew at 200°F(95°C). To change this s

Strona 34 - SCHEMATIC WIRING DIAGRAM

Page 9CDBC-APS/TC/TS/TSR ADJUSTMENTS & OPTIONAL SETTINGS (cont)Water Sensing Threshold Adjustment Procedure1. Make sure the tank is full of water

Komentarze do niniejszej Instrukcji

Brak uwag